Skyjack SJ63 AJ Articulating Boom Lift
Skyjack SJ63 AJ specifications
- Working height
- 69 ft 7 in
- Platform height
- 63 ft 7 in
- Horizontal reach
- 40 ft
- Platform capacity
- 500 lb (2 persons)
- Platform size
- 36 x 96 in
- Stowed width
- 96 in
- Stowed height
- 100 in
- Machine weight
- 21,200 lb
- Drive speed
- 4.5 mph
- Gradeability
- 45%
- Indoor / outdoor use
- Outdoor, rough terrain (4WD); zero tailswing; up-and-over height 27 ft 6 in
- Power
- Deutz TD2.9L4 diesel 74 HP or Kubota WG2503 dual fuel 61 HP; 30.4 gal fuel tank
From the manufacturer’s published specifications. Check the machine’s decals for its exact ratings.
Daily care
Before each shift, do the walk-around and function tests from the operation manual: check engine oil, coolant, hydraulic oil (between the min and max marks), fuel, tires and the platform controls. A qualified person must inspect the machine every 3 months or 150 hours (Skyjack's frequent inspection), and a full annual inspection is due every year.
Manuals and documents
- Operator's manualSJ63 AJ serial 95300317 - 95399999 (covers our 2016 unit, serial 95300809)
- Operator's manualSJ63 AJ+ serial A302000001 - A302099999
- Spec sheetSJ63 AJ (pre-AJ+); sheet edition NA/ENG/03/2018
- Spec sheetSJ63 AJ+ (ANSI A92.20 version, 660/1,000 lb); sheet edition NA/ENG 11/2019
- Training videoSJ46/51/63 AJ (pre-AJ+)
- Training videoSJ45/46/60/63 AJ+; only if the 2019 unit is an AJ+
Skyjack SJ63 AJ at Versi Rentals
Rent by the day, week, or month from our Springville yard, with delivery throughout Utah. Some are also for sale.

Versi Rentals
63 FT ARTICULATING BOOM LIFT FOR RENT

Versi Rentals
Skyjack SJ 63AJ Boom Lift Rental
Available

Versi Rentals
2016 Skyjack SJ 63AJ Boom Lift
2,246 Hrs
Available

Versi Rentals
2019 Skyjack SJ 63AJ Boom Lift
1,398 Hrs · ID 1797
Available
Skyjack SJ63 AJ maintenance schedule
The manufacturer’s preventive maintenance intervals, whichever comes first of hours or time. Every machine in our fleet is kept on this schedule.
- Pre-start inspection and function testsBefore each use / each shift (operator)
- Pre-delivery inspection (PDI)Before each rental, lease or sale
- Frequent inspectionEvery 150 hours or 3 months
- Annual inspectionEvery year